Meacon Automation
Meaconis committed to industrial process automation sensors and instruments since its establishment for decades. The main products are water analysis instruments, recorders, pressure transmitters, flowmeters, and other field instruments.By offering super-qualified products and one-stop service, Meacon has been working in industries as widespread as oil & gas, water & wastewater, and chemical & petrochemical in more than 100 countries, and will take further efforts to provide the most superior service and meet customers’ satisfaction.By 2021, Meacon will have many R&D researchers and engineers, and more than 250 employees in the group. With diverse market needs and global customers, Meacon has established and is establishing its offices in Singapore, Malaysia, India, etc.Meacon is constantly trying to establish strong partnerships with distributors worldwide, integrating itself into the local innovation system and contributing to global technological innovations."Customer-centric": Meacon will continuously be committed to process automation sensors and instruments, and play an indispensable role in the world instrument industries.
Products
MIK-PH160S pH meter
MIK-PH160S industrial pH meter is an online pH analyzer with 4-20mA analog signal, RS-485 digital signal and relay output. Can be used for industrial processes and water treatment processes pH control and support remote data transmission. Features: Easy operation Automatically Temperature Compensation Directly switchable to PH or ORP Large LCD display with background lighting PH or ORP sensors can be connected thanks to the sensor supply integrated in the output Using the setup program: user-friendly programming 4-20mA analog output RS485 communication Relay output Product parameters.
MIK-ORP6050 ORP sensor
MIK-ORP-6050 pH sensor used in ORP measurement is also called primary cell. The primary battery is a system whose function is to convert chemical energy into electrical energy. The voltage of this battery is called electromotive force (EMF).
pH sensor for corrosive medium
MIK-pH-5013A pH sensor is used in PH measurement and is also called primary cell. The primary battery is a system whose function is to convert chemical energy into electrical energy. The voltage of this battery is called electromotive force (EMF).
MIK-LDG Stainless steel body electromagnetic flowmeter
电磁流量计的原则下进行操作Faraday’s law of electromagnetic induction to measure liquid velocity. Following Faraday’s Law, magnetic flowmeters measure the velocity of conductive liquids in pipes, such as water, acids, caustic and slurries. Magnetic flowmeter can be used in water/wastewater industry, chemical, food and beverage, power, pulp, paper, metals, mining and pharmaceutical applications. Features include: Accuracy: ±0.5%,±2mm/s(flowrate<1m/s) Electric conductivity Water: Min.
MIK-LDGR Electromagnetic BTU meter
Meacon electromagnetic BTU meters accurately measure the thermal energy consumed by chilled water in British thermal units (BTU), which is a basic indicator for measuring thermal energy in commercial and residential buildings. BTU meters are usually used in commercial and industrial as well as office buildings for chilled water systems, HVAC, heating systems, etc. Features SUP-LDGR electromagnetic BTU meter(Heat meter) operating principle: Hot (cold) water supplied by a heat source flows into a heat exchange system at a high (low) temperature(a radiator, heat exchanger, or complex system consisting of them),Outflow at low (high) temperature, in which heat is released or absorbed to the user through heat exchange (note: this process includes energy exchange between heating system and cooling system).When water flow through the heat exchange system, according to the flow sensor of flow and matching the temperature of the sensor is given for the return water temperature, and flow through time, through the calculation of the calculator and display the system heat release or absorption.
Vortex flowmeter with temperature and pressure compensation
MIK-LUGB Vortex flowmeter works on the principle of generated vortex and the relationship between vortex and flow by theory of Karman and Strouhal, which specializes in measurement of steam, gas and liquid of lower viscosity. As shown in below illustration, medium flows through bluff body and then vortex is generated, vortices are alternately formed on both sides with opposite directions of rotation, vortices frequency is directly proportional to medium velocity. Through numbers of vortices that is measured by sensor head, medium velocity is calculated, plus flow meter diameter, final volume flow come out. .
MIK-1158S wall mounted ultrasonic flowmeter
MIK-1158S wall mounted clamp on ultrasonic flow meter uses advance circuit design, coupled with excellent hardware that can be switched surfaces. It is easy to operate and with stable performance.
MIK-LZ metal tube rotameter
MIK-LZ Metal Tube Rotameter is a device that measures the volumetric flow rate of fluid in a closed tube. It belongs to a class of meters called variable-area flowmeters, which measure flow rate by allowing the cross-sectional area the fluid travels through to vary, causing a measurable effect.
MIK-PX300 pressure transmitter with display
Pressure transmitter is a common sensor for industrial uses. Widely used in automatic control program like water resources and hydropower, railway, building automation, aerospace, military project, petrochemical, electronic, marine etc. Pressure transmitter is used to measure the gas, steam’s level, density and press.
MIK-PH8001数字pH传感器
IK-PH8001 pH electrode can be used for aquaculture, IoT water quality detection, with digital interface (RS485*1), can be used to measure the change of pH/ORP value in the aqueous solution system within the range, and it has standard RS485 Modbus RTU protocol interface function, Can communicate with the host computer remotely Communication Protocol Communication interface: RS485 Port setting: 9600,N,8,1 (default) Device address: 0×01 (default) Protocol specification: Modbus RTU Instruction support: 0×03 read into register 0×06 write register | 0×10 write register continuously.